Researchers at Kanazawa University report in The Journal of Physical Chemistry Letters how to simulate 3D atomic force microscopy images of out-of-equilibrium systems involving biomolecules. The approach makes use of a celebrated equation from thermodynamics applicable to non-equilibrium situations.
Three-dimensional atomic force microscopy (3D-AFM) is a technique used for probing the distribution of solvent molecules at solid–liquid interfaces. Initially applied for studying situations where the solvent is water, the method is now also being used for other molecules. A recent development is to use 3D-AFM for resolving the organization of biopolymers such as chromosomes or proteins within cells. Due to the complexity of such systems, however, simulations of the 3D-AFM imaging process are needed to assist with its interpretation. Simulation methods developed so far have assumed that the probed system is in equilibrium during the AFM scan cycle. This limits their validity to situations where the solvent molecules move much faster than the scanning probe. Now, Takeshi Fukuma from Kanazawa University and colleagues have developed a 3D-AFM simulation approach that works for systems not in equilibrium, applicable to situations where molecular motion happens on timescales comparable to or larger than that of the AFM probing cycle.
The basic principle of AFM is to make a very small tip, attached to a cantilever, scan a sample’s surface. The tip’s response to height differences in the scanned surface provides structural information of the sample. In 3D-AFM, the tip is made to penetrate the sample, and the force experienced by the tip is the result of interactions with nearby (parts of) molecules. For a given horizontal (xy) position of the tip, the dependence of the force F on the tip’s vertical (z) position as it penetrates into the sample is captured in a force–distance (F versus z) curve. Combining all force–distance curves obtained during the xy scan gives the 3D-AFM image.
Fukuma and colleagues considered the situation where an AFM tip probes a globular biopolymer, and modeled both tip and molecule as beads connected by springs (2000 beads for the molecule, 50 beads for the tip). They calculated the force–distance curves by using the so-called Jarzynski equality, an equation that relates the free energy difference between two states of a system to the work (proportional to the force) required to go from one state to the other. Importantly, the equality holds for non-equilibrium situations.
The researchers were able to show that the simulations reproduced the internal structure of the biopolymer, with some fiber features being clearly observable. They also looked at how the scanning velocity affects the simulation results, and found that there is an optimum velocity range for the vertical (z) scan. Finally, Fukuma and colleagues simulated 3D-AFM images of cytoskeleton fibers for which experimentally obtained 3D-AFM images exist, and found that the simulations agree well with the experiment. The scientists therefore concluded that their method “is applicable to various fibers in cells such as DNA and so on by changing parameters such as stiffness, providing an important theoretical base for such experimental measurements.”
【Movies】
https://nanolsi.kanazawa-u.ac.jp/wp-content/uploads/2022/06/movie-1_sumikama.mp4
Movie 1.
Probe penetration into the biopolymer. The biopolymer is a single fiber colored red to blue from end to end.
https://nanolsi.kanazawa-u.ac.jp/wp-content/uploads/2022/06/movie-2_sumikama.mp4
Movie 2.
A 3D-AFM image. This movie shows a series of xy slices from high to low z.
Background
3D Atomic force microscopy (3D-AFM)
The general principle behind atomic force microscopy (AFM) is to make a very small tip scan the surface of a sample. During this horizontal (xy) scan, the tip, which is attached to a small cantilever, follows the sample’s vertical (z) profile, inducing a force on the cantilever that can be measured. The magnitude of the force at the xy position can be related to the z value; the xyz data generated during a scan then result in a height map providing structural information about the investigated sample.
In 3D-AFM, the sample is penetrated by the (oscillating) scanning tip, so not only the surface, but also the inside of a sample can be probed. To correctly interpret images obtained by means of 3D-AFM, it is important to perform simulations that, based on a structural model, calculate the expected 3D-AFM images, which can then be compared to what was experimentally recorded.
Takeshi Fukuma from Kanazawa University and colleagues have now developed a simulation approach that is applicable to non-equilibrium situations — important for studying biologically relevant systems such as biomolecules in a cell.
[Funder]
This work was supported by World Premier International Research Center Initiative (WPI), MEXT, Japan, JST, PRESTO (JPMJPR20K6), Japan, and WPI-NanoLSI Transdisciplinary Research Promotion Grant from Kanazawa University; JSPS KAKENHI (19K22125 and 20H00345); and JST Mirai-Project (18077272), and the Academy of Finland (314862).
[Reference]
Title: Computed three-dimensional atomic force microscopy images of biopolymers using the Jarzynski equality
Journal: The Journal of Physical Chemistry Letters 13, 23, 5365–5371 (2022)
Authors: Takashi Sumikama, Filippo Federici Canova, David Z. Gao, Marcos Penedo, Keisuke Miyazawa, Adam S. Foster, and Takeshi Fukuma.
DOI: 10.1021/acs.jpclett.2c01093